4.5.12 Vibration endurance. The scale error shall be noted at the existing atmospheric
pressure. The instrument shall be subjected to a cyclic vibration endurance test in accordance
with figure 2 and procedure I, method 514, of MIL-STD-810 for a 3-hour period. At the end of
the vibration period, the scale error at atmospheric pressure shall again be noted. The difference
between the reading determined before and that determined after vibration, after correction for
any changes in atmospheric pressure, shall not exceed 100 feet.
FIGURE 2. Vibration testing amplitude-frequency curve.