MIL-DTL-27190C
3.3.3 Pointer. The pointer shall conform to figure 1 and shall be suitable for integral
lighting. The length shall be such that the tip of the pointer will extend into the scale a distance
equal to 1/3 to 2/3 the length of the shortest graduation.
ELECTRICAL ZERO
REFERENCE MARK
3
4
HYD
2
40° ± 0° 15'
X 1000
0
1
DIAL
0.093
3
SHADED AREA WHITE
16
27
64
7
64 MAX
POINTER
Dimensions in inches.
Unless otherwise specified, tolerances: fractions ±1/64; decimals ±0.010.
FIGURE 1. Dial and pointer.
3.3.3.1 Pointer finish. The lighted portion of the pointer shall be finished in accordance
with FED-STD-595, color number 37875.
3.3.4 Dial. The dial shall conform to figure 1. A minimum diameter of 15/16 inch shall
be maintained across the outside of the graduations. The 2,000-psi graduation shall be located on
the horizontal centerline at the left side of the dial. The graduation for each 500-psi increment
shall be 40 degrees ± 0 degrees 15 minutes apart.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.