MIL-DTL-17896E
Movement of the index hand shall be free of backlash, hanging, or irregular motion when the
pressure is varied uniformly. These tests may be combined with those of 4.6.8.
4.7 Rejection and retest. Any unit failing to meet the individual tests and the sampling
plan A or B tests shall be cause for rejection of the entire lot. Barometers that have been rejected
may be replaced or repaired and the lot retested using a tightened sample size in accordance with
verification level II of MIL-STD-1916. Prior to retesting, the manufacturer shall provide in
writing to the procuring activity all corrective actions taken to correct the defect(s). Units
rejected after retest shall not be resubmitted and the lot shall be rejected unless specific approval
is authorized by the procuring activity granting additional corrective actions and testing.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When packaging of material is to be performed by DoD or in-
house contractor personnel, these personnel need to contact the responsible packaging activity to
ascertain requisite packaging requirements. Packaging requirements are maintained by the
Inventory Control Point's packaging activity within the Military Service or Defense Agency, or
within the military department's system command. Packaging data retrieval is available from the
managing Military Department's or Defense Agency's automated packaging files, CD-ROM
products, or by contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful,
but is not mandatory.)
6.1 Intended use. The intended use of the barometers covered by this document is as follows:
Type I - for measuring atmospheric air pressure.
Type II - for measuring atmospheric air pressure in pressure controlled areas such as
submarines or boiler rooms.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of this specification.
b.
Type (see 1.2).
c.
Specific issue of individual documents referenced (see 2.2.1 and 2.3).
d.
When first article inspection is required (see 3.1).
e.
Required sampling plan tests A or B (see 4.4).
f.
Packaging (see 5.1).